PULCOM V10A / V10S
Features
Intelligent Judgment Control
SPC control (post-process) and display and output of ellipticity, chattering judgment, and processing status (in-process) are available, enabling control with a high added value.
Multipoint Measurement
Hardware that allows connection of a maximum of 4 measuring heads and software that allows judgment of a maximum of 32 items provide the optimum configuration for simultaneous parallel processing and multi-item judgment.
(Additionally, mounting the PULCOM V11 and V11D expansion units enables connection of a maximum of 32 measuring heads.)
Significantly Enhanced Usability
A 6.5-inch bright TFT color LCD with a touch panel has been adopted for the display unit. Simply touch the screen of the setting that you wish to set or change when making adjustments or performing other operations. This significantly enhances the usability.
Many More Display Functions
The real-time graphic display for in-process judgment enables the processing status to be grasped at a glance, simplifying discovery of problems. (A signal can be optionally output in the event of a problem.) The processing status can be replicated when a defective workpiece is discovered in post-processing, simplifying analysis of the cause of the defect. For post-process judgment, the display can be tailored to the functions used, e.g., display of the list of all judgment items and display of statistically processed data.
Meter Display
The processing status can be displayed on the meter of the LCD for in-process measurement, providing a realistic view of the processing conditions.
More Standard Functions
The unit has a variety of functions as standard, including auto-mastering, operational expression input, smoothing, and extended range display/high resolution.
Data List Display
Display of a workpiece diagram, judgment items, judgment values, and judgment results in a list facilitates judgment of the current status.
Supports 4 Languages
The display can be switched to Japanese, English, Chinese or Korean, so it can be used easily overseas. *However, the measurement item names are displayed only in Japanese and English.
Size Shift Function for Multi-Product Lines (Option)
Combing this unit with an extended range measuring head enables judgment of workpieces of multiple types, multiple axes, etc. without changing the setup. A maximum of 1280 size shifts can be registered.
The processing status can be displayed in real time.
In-Line Roundness (Option)
Roundness can be measured during or after processing. The measurement results are displayed in polar coordinates and output as a “pass” or “fail” judgment. In addition, the provision of an FFT analysis function facilitates judgment of chattering and an equal-diameter strain circle, too.
Fieldbus Support
CC-Link, PROFIBUS, and DeviceNet (option) are supported.
The unit can communicate with upper devices like NC and PLC via one serial cable. Also, since the measurement data can be output, support is also available for IoT. Due to this, the unit is released from the multiple wiring of the conventional I/O, and so the effort expended on design, assembly, maintenance, etc. can be reduced.
Detachable Front Panel (V10S)
The front panel is detachable, so it is possible to embed the unit easily in the user device’s operation panel. Install the main unit inside the control panel of the user's device.
Expanded screen configuration

External view


Specifications
✓: Available -: Not available
Basic specifications | |
Product name | PULCOM V10A |
Representative model | E-PV 15xxxx |
Applications | In-process/Post-process |
Display method | 6.5-inch TFT VGA color LCD (16 colors) |
Display items | Measurement results/List of items/Various settings (Meter display is possible during the in-process.) |
Measurement value display range | Switching between ±50 μm, ±100 μm, ±250 μm, ±500 μm, ±1000 μm, ±2500 μm, and ±5000 μm |
Resolution | Select from 0.01 μm, 0.05 μm, 0.1 μm, 0.5 μm, and 1 μm |
Display unit | Select from μm, mm, and inch. (Basically, these are only supported for overseas markets.) |
Human interface | Resistive touch panel |
Sampling speed | 1 msec or less |
Data update time | 8 msec |
Display isolation/Panel type model | ✓(PALCOM V10S) |
IP code | IP54 equivalent (front panel only) |
Ambient usage temperature/Humidity | 0 to 50℃/10 to 90% R.H. (no condensation) |
Vibration resistance/Shock resistance | JIS C1003 compliant |
CE mark | Individual support |
Exterior dimensions (W) x (D) x (H)/Weight | 287×327.6×159 mm/7.0 kg |
Power source/Power consumption | AC85 to 250 V/70 VA |
Accessories | Fuse/Power cable |
External I/F | |
I/O | ✓ |
Ethernet | ― |
RS-232C | ✓(option) |
Analog input | ✓(Special support) |
HLS | ✓(V11/V11D connection options) |
Fieldbus | ✓(Option/CC-Link), DeviceNet, PROFIBUS |
External memory | |
CF | ✓ |
USB | ― |
Main functions/Options | |
No. of connected detectors | 4 (Expansion available with V11/V11D) |
No. of measuring items | Max.32 |
Judgment output | Max 20 E.g. 20 judgment outputs: Simultaneous processing 1 5 judgment outputs for each: Simultaneous processing 4 |
Options
Options | |||
Product code | Product name | Model | Remarks |
0301003 | LVDT board | - | LVDT gauge 4CH connection available |
0930316 | PHA board | - | Γ-DII/PHA series 4CH connection available |
4206628 | 2CH counter board AE50503-G500/H500 | - | For Σ-D/Γ-D |
4206629 | 4CH counter board AE50502-G500/H500 | - | For Σ-D/Γ-D |
0301006 | Size shift board (4CH hardware only) | - | LVDT gauge size shift board (One of the size shift functions, 0301007, 0930112, or 0930109, is required.) |
0301007 | Size shift function up to 6D (software only) | - | LVDT gauge diameter difference support: up to 6D (diameter) |
0930112 | Size shift function 7D-20D (software only) | - | LVDT gauge diameter difference support: up to 20D (diameter) |
0930109 | Size shift function 21D or more (software only) | - | LVDT gauge diameter difference support: from 20D (diameter) to 40D |
4300473 | Scale gauge software Workpiece switching 40 | - | Scale gauge (Σ-D/Γ-D/Γ-DII/PHA) diameter difference support: up to 40D (diameter) |
4300474 | Scale gage software Workpiece switching 128 | - | Scale gauge (Σ-D/Γ-D/Γ-DII/PHA) diameter difference support: up to 128D (diameter) |
0930148 | Power cable 6 m | - | V10A power cable |
0930155 | Power cable custom length (for 1 m) | - | Price per m for length specified |
0930157 | PULCOM V11 | E-PV11 | LVDT gauge 4CH connection available |
0930158 | V11 size shift board | - | LVDT gauge (One of the size shift functions, 0301007, 0930112, or 0930109, is required.) |
0930169 | V11 CE Marking support | - | CE Specification |
0930294 | PULCOM V11D | E-PV11D | Γ-DII/PHA series 4CH connection available |
0930105 | HLS high-speed communication board | - | Board for communication with V11 and V11D with a V11 0.5 m connection cable |
0930152 | 24-V 6 m power cable | - | Common to V11 and V11D |
0930159 | 24-V power cable custom length (for 1 m) | - | Common to V11 and V11D Price per m for length specified |
0930154 | V11 termination cable | - | V11, V11D and PULCOM V9 unit (CC/PB/DN) Essential for connection terminals |
0930161 | V11 connection power cable 0.5 m | - | Common to V11, V11D |
0930162 | V11 connection power cable 1 m | - | Common to V11, V11D |
0930164 | V11 connection power cable 3 m | - | Common to V11, V11D |
0341217 | V11 connection power cable 6 m | - | Common to V11, V11D |
0930163 | V11 connection power cable custom length (for 1 m) | - | V11, V11D common Price per m for length specified |
0341219 | V11 connection cable 0.5 m | - | Common to V11, V11D |
0930165 | V11 connection cable 1 m | - | Common to V11, V11D |
0930166 | V11 connection cable 3 m | - | Common to V11, V11D |
0930167 | V11 connection cable 6 m | - | Common to V11, V11D |
0930168 | V11 connection power cable custom length (for 1 m) | - | V11, V11D common Price per m for length specified |
0930290 | V11 24 V power supply unit 30 W | - | Common to V11, V11D |
0930291 | V11 24 V power supply unit 60 W | - | Common to V11, V11D |
0930292 | V11 24 V power supply unit 120 W | - | Common to V11, V11D |
0936005 | GE-10V externally mounted unit type 1CH | - | GE series connection options |
0936006 | GE-10V externally mounted unit type 2CH | - | GE series connection options |
0936007 | GE-10V built-in board type 1CH | - | GE series connection options |
0936008 | GE-10V built-in board type 2CH | - | GE series connection options |
0936155 | GE-10V AE sensor board built-in type GC (gap crash) | - | GE series connection options |
0936156 | GE-10V externally mounted type controller GC (gap crash) | - | GE series connection options |
0936651 | AB-10V externally mounted unit type | - | AB-10V connection options |
0936560 | AB-10V built-in board type | - | AB-10V connection options |
0930103 | BCD/BINARY (open drain) output functiona | - | Including I/O 2 board (open drain) and I/O 2 cable of 6 m |
0930104 | Analog data output function | - | |
0930106 | RS-232C output function | - | Judgment results/Measurement values/Statistical data serial output |
0999095 | RS-232C cable (9P-9P) | - | 5m |
0937500 | DataLink X | - | PC application software (RS-232C output function is required separately) |
0930110 | Auto-calibration | - | Calibration feature through external input |
0930114 | Measuring items (5 items or more per item) | - | |
0930115 | Memory (internal synchronization, automatic synchronization) | - | For in-processing: MAX, MIN, P-P and others |
0930116 | Memory (external synchronization) | - | For in-processing: MAX, MIN, P-P and others |
0930111 | P100 (internal synchronization, automatic synchronization) | - | For a fixed period after the occurrence of synchronization, the measurement value is stored in integral memory. |
0930113 | P100 (external synchronization) | - | A fixed time from the occurrence of synchronization, the measurement value is stored in integral memory |
0930123 | Memory (for post-process) | - | Controlled by the I/O measurement start signal, MAX, MIN, P-P |
0930124 | External auto zeroing function | - | Gauge zeroing via the external signal |
0930121 | Roundness measuring function (polar coordinate display, FFT analysis) | - | Roundness display and the judgment of the vibration amount and each frequency component amount |
0930122 | Statistical processing (no judgment output) | - | Statistical display only |
0930125 | Statistical processing (with output) | - | With statistical result output |
0930126 | Workpiece switching (tolerance switching) | - | Switching the judgment point value |
0930127 | Workpiece diagram drawing | - | Workpiece diagram surface display |
0930128 | Average calculation | - | Measurement of the average value of the post-processed workpieces within a fixed time |
Options | |||
Product code | Product name | Model | Remarks |
0930129 | Repeat counter for tool correction | - | For post-process: the finished dimension is monitored and a signal is output to the in-process control section, etc. (paired with 0930133) |
0930131 | RUN signal | - | If not within the signal cut range during in-process measurement, the RUN signal output is turned ON. |
0930132 | In-process processing status display (dimension problem output) | - | Graph display of the status during in-process processing and the detection of a diameter problem caused by black skin residue and grit |
0930135 | Infinity function | - | The measurement value is scaled out so that unnecessary output does not appear at any time other than during judgment. |
0930133 | External grade | - | For in-process: correction of the finished dimensions based on signal input from outside (paired with 0930129) |
0930134 | Signal point shift/External zero shift | - | For in-process: The post inspection device’s judgment results are input, and the zero point is corrected. |
0930136 | Zero shift | - | For in-process: The drift of the finished dimensions is monitored, and the zero point is corrected. |
0930140 | Temperature compensation | - | A function for correcting the measurement value using the input temperature figure. (The temperature sensor is required separately.) |
0937915 | Temperature sensor (for coolant, mounted external diameter φ 10) | - | |
0937925 | Temperature sensor (for the workpiece surface temperature, mounted external diameter φ 11) | - | |
0937930 | Temperature sensor (for the workpiece surface temperature, mounted external diameter φ 10) | - | |
0345589 | CF card | - | Saving the set value/Writing the set value/Saving the statistical data, etc. |
0346012 | V10A touch panel protection sheet (5 sheets per box) | - | |
0930141 | Tilt type amp mounting stand | - | |
0930061 | Printer (Japan specification) RP-D10-JP | - | |
0930062 | Printer (USA specification) RP-D10-US | - | |
0930076 | Printer (Europe specification) RP-D10-EU | - | |
0930054 | TP-B10CH (unrecorded RP-D10 10 volumes) | - | |
0930189 | V10S 10 m front I/F cable | - | |
0301010 | I/O 1 board (open drain) | - | |
0341202 | 6 m I/O cable | - | |
0930142 | I/O 1 cable custom length (for 1 m) | - | Price per m of length specified |
0301015 | I/O 2 board (open drain) | - | |
0341200 | 6 m I/O 2 cable | - | |
0341201 | I/O 2 cable custom length (for 1 m) | - | Price per m of length specified |
0301016 | I/O 3 board (open drain) | - | |
0301018 | I/O 3 board (input only) | - | |
0930144 | 6 m I/O 3 cable | - | |
0930147 | I/O 3 cable custom length (for 1 m) | - | Price per m of length specified |
0930145 | Condition file creation fee | - | |
0930146 | Changed specification creation fee | - | |
0930309 | V10 CUnet board | - | With 0.5 m PULCOM V9 unit (CC/PB/DN) connecting CUnet cable |
0930311 | 6 m CUnet cable | - | For PULCOM V9 unit (CC/PB/DN) connection |
0937006 | PULCOM V9 CC (CC-Link connection unit) | E-PV9U30 | CUnet board/cable are required separately |
0937007 | PULCOM V9 PB (PROFIBUS connection unit) | E-PV9U31 | CUnet board/cable are required separately |
0937009 | PULCOM V9 DN (DeviceNet connection unit) | E-PV9U33 | CUnet board/cable are required separately |
0937060 | PULCOM V9 unit (CC/PB/DN) common power cable | - | |
0937061 | 1 m CC-Link dedicated cable | - | |
0937062 | CC-Link dedicated cable custom length (for 1 m) | - | Price per m of length specified |
0937076 | 1 m DeviceNet cable | - | |
0937077 | DeviceNet cable custom length (for 1 m) | - | Price per m of length specified |
0937080 | 1 m PROFIBUS cable | - | |
0937081 | PROFIBUS cable custom length (for 1 m) | - | Price per m of length specified |
0930313 | Data transfer function | - | Fieldbus data transfer function |