Driven by its own voluntary targets, Tokyo Seimitsu has been committed to making its manufacturing sites, the Hachioji and Tsuchiura plants, more energy efficient over the years. To achieve the Japanese government’s 2030 greenhouse gas reduction target established under the Paris Agreement, we have set medium- and long-term CO₂ reduction targets regarding the energy (Scope 1 and Scope 2) that our two plants use for business, production, and R&D activities, and we continuously control and assess the progress. Although the two plants successfully reduced their CO₂ emissions, the company-wide CO₂ emissions increased as we put a new plant into operation and used more energy in expanding our business. To ensure we achieve our medium- and long-term targets, we will promote the reduction of electricity consumption by upgrading to more energy-efficient equipment, from fiscal 2026 onwards. At the same time, we will actively increase the use of renewable energy, low-carbon electricity, and non-fossil electricity, accelerating our decarbonization efforts.

CO₂ Emission Reduction Targets and Fiscal 2025 Results

CO₂ Emission Reduction  Scope1+Scope2(*1、*2)

Benchmark emissions

(FY2018)

12,312 t-CO₂

 

FY2025

FY2026

FY2030

35% reduction compared to FY2018

38% reduction compared to FY2018

50% reduction compared to FY2018

Reduction target

Reduction target

Reduction target

8,003 t-CO₂

7,634 t-CO₂

6,156 t-CO₂

Set in 2021

Set in 2026

Set in 2021

Result (FY2025)

FY2025

3.93% increase compared to FY 2018

Result

12,796 t-CO₂

Locations covered: Tokyo Seimitsu Co., Ltd. Hachioji Plant, Hanno Plant (construction completed in July 2023), Tsuchiura Plant, and Battery Testing Center Fukushima Site [former Furudono Plant] (business transferred in October 2023)

*¹ Direct GHG emissions by the Company (emissions from fuel combustion, on-site power generation, and industrial processes)

*² Indirect emissions resulting from the use of electricity and heat supplied by other companies (e.g. emissions associated with electricity purchased from electric power companies)

Actual and Planned CO₂ Emissions

CO₂ emissions compared to the reference year

CO Emission Reduction Targets

Emissions by scope and production volume intensity (5 years)

Emissions by scope and production volume intensity (5 years)
  Unit FY2021 FY2022 FY2023 FY2024 FY2025
Total CO₂ emissions(Scope1 and Scope2) t-CO₂ 8,191 8,257 11,598 12,733 12,796
  Scope1 Gas(LPG) t-CO₂ 51 54 70 71 79
Fuel*1 t-CO₂ 43 45 47 47 40
Scope2 Electricity t-CO₂ 8,097 8,158 11,481 12,615 12,676
CO₂ emissions production volume intensity(Scope1 and Scope2) t-CO₂ /
million yen
0.080 0.074 0.111 0.103 0.091

Locations covered: Tokyo Seimitsu Co., Ltd.
Until fiscal 2022: Hachioji Plant and Tsuchiura Plant
From fiscal 2023: Hachioji Plant, Hanno Plant (from July), Tsuchiura Plant, and Battery Testing Center Fukushima Site [former Furudono Plant] (after business transfer in October)
*¹ Fuels calculated: Volatile oil, kerosene, and light oil

Eco-Factory

Promotion of Global Warming Prevention (Toward a Decarbonized Society)

Almost all the greenhouse gases emitted by the Company are from the CO₂ equivalent of electricity purchased and used during the plant operations. As a global warming prevention measure, we are promoting initiatives focused on the procurement of renewable electricity*¹ and energy conservation.

Specific CO₂ Emission Reduction Examples

Procurement of renewable electric power*¹

Installation/maintenance of solar power generation facilities (Hachioji Plant, Hanno Plant, and Tsuchiura Plant)

Solar Power Generation Facilities Capacity and Amount of Solar Power Generation by Plant

Plant Unit FY2022 FY2023 FY2024 FY2025
Hachioji Solar power generation facilities capacity kW 406  406 406 406
Amount of solar power generation  MWh 416.2 377.2 463.2 450.7
Hanno Solar power generation facilities capacity kW - 713 713 713
Amount of solar power generation MWh - 224.6 503.5 517.7
Tsuchiura Solar power generation facilities capacity kW 50 50 50 50
Amount of solar power generation MWh 53.5 58.0 55.4 55.4
Hachioji Plant
Hachioji Plant
Hachioji Plant
Hachioji Plant
Hanno Plant
Hanno Plant
Tsuchiura Plant
Tsuchiura Plant

Switchover to low-carbon electricity/CO₂-free electricity*²

Hachioji Plant
Tsuchiura Plant
Furudono Plant

: Switched in March 2020
: Switched in November 2020
: To switch in May 2024

Purchase of non-fossil certificates

Hachioji Plant

: Started purchasing in fiscal 2025

*¹ Renewable electric power

Electricity generated from renewable energy sources

*² CO₂-free electricity

Electricity that emits no CO₂ when generated. This refers to electricity that is virtually CO₂-free, utilizing environmental value derived from renewable energy sources that do not emit CO₂ 

Electricity Use

Electricity Use

Locations covered: Tokyo Seimitsu Co., Ltd.
Until fiscal 2022: Hachioji Plant and Tsuchiura Plant
From fiscal 2023: Hachioji Plant, Hanno Plant (from July), Tsuchiura Plant, and Battery Testing Center Fukushima Site [former Furudono Plant] (after business transfer in October)

 

 

Specific Examples of Efforts to Promote Energy Conservation (Environmental System Program Initiatives)

Capital investment (Approx. 64 million yen)

Pumps, ventilators, LED lights, and air conditioner upgrade

Energy conservation measures through operational improvements

Timer operation, thinned-out operation, and scheduled operation

Turning off of unnecessary lights

Maintenance (cleaning)

Company-owned solar power generation facilities

Reduction of environmental impact through productivity enhancement

Optimization of the work processes

Yield improvement and thorough quality control

Prioritizing the use of electric vehicles (EVs)

Management of Environmental Impact on the Atmosphere

The Company manufactures freezers that use HFC* gases, for use in semiconductor manufacturing equipment. We also possess freezers for use in shipping inspections of semiconductor manufacturing equipment. In order to comply with the “Act on Rational Use and Proper Management of Fluorocarbons,” we have a system in place to inspect and maintain freezers, refill and collect fluorocarbons, report on leaks, etc. in an appropriate manner.

* Hydrofluorocarbons (HFCs)

Hydrofluorocarbons do not contain chlorine atoms that deplete the ozone layer and are therefore used as chlorofluorocarbon substitutes in air conditioners and other coolants

Atmospheric Gas Discharge

Other Gases Unit FY2021 FY2022 FY2023 FY2024 FY2025
CH₄ t-CO₂  0.0 0.0 0.0 0.0 0.0
N₂O t-CO₂  0.0 0.0 0.0 0.0 0.0
HFC* t-CO₂  61.6 19.1 65.5 111.8 234.5
PFC t-CO₂  0.0 0.0 0.0 0.0 0.0
SF₆ t-CO₂  0.0 0.0 0.0 0.0 0.0

Locations covered: Tokyo Seimitsu Co., Ltd. Hachioji Plant, Hanno Plant (from July 2023), and Tsuchiura Plant